Product Details:
Minimum Order Quantity | 1 Unit |
Size | L385XB183XH229 |
Available Voltage | 85 TO 300V AC/DC 50/60 Hz |
Brand | TRIDENT |
End Connection | 1/2 Inch BSP |
Fluid Temperature | 75 Deg C |
Power Source | Single Phase 230 Volts |
Pressure | 10Kg/cm2 |
The LDV Series:
*Condensate sensing Type
*Zero Air Loss
*Patented Design
*Noise less
*Fault Tolerant System
The LDV series condensate sensing type automatic Drain valves is the latest advancement in drain valve technology. These valves sense the condensate level for activation ensuring absolutely no loss of compressed air and hence results in enormous energy saving , This type of condensate sensing drain valves are highly efficient and reliable. Fault tolerant system is switching over into timer mode automatically while LDV fails to operate due to sensor failure. Timing cycle is every 2 min for a period of 2 seconds.
Features:
1) The electronic level control ensures proper draining of condensate and avoids unnecessary of air loss.
2) All the function of the valve are accurately indicated by the yellow LED.
3) Test switch (or) manual drain allows function test at any time.
4) Intelligent Controller detects probe failure and indicates Red LED for potential free relay NO change to NC.
5) Noise less as air is not discharged.
MODEL | LDV 3000 |
Input voltage(AC/DC) | 85 TO 300VAC 50/60 Hz |
Average Power Consumption (Watts) | 12 |
Min.Working Pressure(Kg/cm2(g) | 4 |
Max.Working Pressure(Kg/cm2(g) | 10 |
Valve Orifice (mm) | 4 |
End Connection Inlet | 1/2” BSP(M) |
End Connection outlet | ½” BSP (F) |
Environmental Protection | IP 54 |
Valve Dimension LXBXH (mm) | 385X183X229 |
Max.Flud Temp.(Deg C) | 75 |
Max.Condensate Discharge Qty.at 7kg/cm2(g)(Liters/Hours) | 675 |
Air Compressor After cooler (m3/Hr) | 4248 & above |
Wet Air Receiver (m3) | 12 & above |
Dry Air Receiver (m3) | 12 & above |
Pre Filter(m3/Hr) | 30582 & above |
Refrigeration Dryer (m3/Hr) | 8495 & above |
After Filter (m3/Hr) | 30582 & above |
Weight (Kg) | 7.0 |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Unit |
Media | Air |
Drain Time | 2 min for a period of 2 seconds. |
Size | L225XB127XH164 |
Available Voltage | 85 TO 300V AC/DC 50/60 Hz |
Brand | TRIDENT |
End Connection | 1/2 Inch BSP |
Fluid Temperature | 75 Deg. C |
Power Source | Single phase 230 volts |
The LDV Series:
*Condensate sensing Type
*Zero Air Loss
*Patented Design
*Noise less
*Fault Tolerant System
The LDV series condensate sensing type automatic Drain valves is the latest advancement in drain valve technology. These valves sense the condensate level for activation ensuring absolutely no loss of compressed air and hence results in enormous energy saving , This type of condensate sensing drain valves are highly efficient and reliable. Fault tolerant system is switching over into timer mode automatically while LDV fails to operate due to sensor failure. Timing cycle is every 2 min for a period of 2 seconds.
Features:
1) The electronic level control ensures proper draining of condensate and avoids unnecessary of air loss.
2) All the function of the valve are accurately indicated by the yellow LED.
3) Test switch (or) manual drain allows function test at any time.
4) Intelligent Controller detects probe failure and indicates Red LED for potential free relay NO change to NC.
5) Noise less as air is not discharged.
MODEL | LDV 2000 |
Input voltage(AC/DC) | 85 TO 300VAC 50/60 Hz |
Average Power Consumption (Watts) | 12 |
Min.Working Pressure(Kg/cm2(g) | 4 |
Max.Working Pressure(Kg/cm2(g) | 10 |
Valve Orifice (mm) | 15 |
End Connection Inlet | 1/2” BSP(M) |
End Connection outlet | ½” BSP (F) |
Environmental Protection | IP 54 |
Valve Dimension LXBXH (mm) | 225X127X164 |
Max.Flud Temp.(Deg C) | 75 |
Max.Condensate Discharge Qty.at 7kg/cm2(g)(Liters/Hours) | 185 |
Air Compressor After cooler (m3/Hr) | 1019 to 3398 |
Wet Air Receiver (m3) | 4 to 10 |
Dry Air Receiver (m3) | 4 to 10 |
Pre Filter(m3/Hr) | 8495 to 27184 |
Refrigeration Dryer (m3/Hr) | 2209 to 6796 |
After Filter (m3/Hr) | 8495 to 27184 |
Weight (Kg) | 3.2 |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Unit |
Media | Air |
Drain Time | 2 min for a period of 2 seconds. |
Size | L141XB60XH127 |
Available Voltage | 230 Volts |
Brand | TRIDENT |
End Connection | 1/2 inch BSP |
Fluid Temperature | 75 Deg C. |
Power Source | 85 TO 300V AC/DC 50/60 Hz |
The LDV Series:
*Condensate sensing Type
*Zero Air Loss
*Patented Design
*Noise less
*Fault Tolerant System
The LDV series condensate sensing type automatic Drain valves is the latest advancement in drain valve technology. These valves sense the condensate level for activation ensuring absolutely no loss of compressed air and hence results in enormous energy saving , This type of condensate sensing drain valves are highly efficient and reliable. Fault tolerant system is switching over into timer mode automatically while LDV fails to operate due to sensor failure. Timing cycle is every 2 min for a period of 2 seconds.
Features:
1) The electronic level control ensures proper draining of condensate and avoids unnecessary of air loss.
2) All the function of the valve are accurately indicated by the yellow LED.
3) Test switch (or) manual drain allows function test at any time.
4) Intelligent Controller detects probe failure and indicates Red LED for potential free relay NO change to NC.
5) Noise less as air is not discharged.
MODEL | LDV 1000 |
Input voltage(AC/DC) | 85 TO 300VAC 50/60 Hz |
Average Power Consumption (Watts) | 12 |
Min.Working Pressure(Kg/cm2(g) | 2 |
Max.Working Pressure(Kg/cm2(g) | 10 |
Valve Orifice (mm) | 4 |
End Connection Inlet | 1/2” BSP(F) |
End Connection outlet | 6mm Hose barb |
Environmental Protection | IP5 4 |
Max.Flud Temp.(Deg C) | 75 |
Max.Condensate Discharge Qty.at 7kg/cm2(g)(Liters/Hours) | 50 |
Air Compressor After cooler (m3/Hr) | 850 |
Wet Air Receiver (m3) | 2 |
Dry Air Receiver (m3) | 2 |
Pre Filter(m3/Hr) | 6796 |
Refrigeration Dryer (m3/Hr) | 1699 |
After Filter (m3/Hr) | 6796 |
Valve Dimension LXBXH (mm) | 141X60X127 |
Weight (Kg) | 1.25 |
Additional Information:
Product Details:
Usage/Application | Air |
Pressure | High Pressure |
Valve Size | 3/4" |
Media | Air |
Material | Stainless Steel |
Brand | Ingersoll-Rand |
Product Details:
Usage/Application | Air |
Pressure | 17.25bar |
Valve Size | 0.25-0.50 NPT |
Media | Air |
Drain Time | 0.5-45min |
Material | Brass/Bronze |
Brand | Ingersoll-Rand |
Coil Voltage | 230/240VOLTS |
Dimension | 121X89X51mm |
Input Voltage | 230/240VOLTS |
Product Details:
Material | Aluminium |
Brand | Trident |
Usage/Application | Air |
Pressure | Medium Pressure |
Valve Size | 1/2 Inch Bsp |
Media | Air, Gas |
Size | 141X60X127mm |
Coil Voltage | 85-300 |
Input Voltage | 230Volts |
Weight | 1.25Kg |
End Connection | 1/2 Inch BSP Inlet |
Fluid Temperature | &5 Degree celcious |
Power Source | Electric |
Frequency | 50/60 hz |
Working Pressure | 10 Bar |
Voltage | 85-300VAC |
Efficiency | Condensate Discharge 50 Liter/Hr |
Automation Grade | Automatic |
Model Name/Number | LDV1000 |
Product Type | Condwnsate Auto Drain valve |
Condition | New |
I Deal In | New Only |
Color | White |
Additional Information:
Product Details:
Usage/Application | Air |
Pressure | High Pressure |
Valve Size | 0.25-0.50 |
Media | Air |
Material | Stainless Steel |
Brand | Ingersoll-Rand |
Coil Voltage | 230/240VOLTS |
Input Voltage | 230/240VOLTS |
Additional Information: